+ Modbus client
+***************
+
+``NewTCPClient`` supplies a caller-owned, serialized connection through
+``Client``. Connect selects the configured unit and has a two-second
+timeout. A request has a one-second write deadline and a two-second
+response deadline, both measured from its start. Caller deadlines and
+cancellation can stop it earlier. Each response must match the
+transaction, unit, function, length, and write acknowledgement.
+Supported functions are 01, 02, 03, 05, 15, and 16. No external Modbus
+package is required.
+
+In-memory stream tests check request bytes, response validation,
+exceptions, truncation, cancellation, and timeouts. They do not verify a
+physical host or TCP network behavior.